page-template,page-template-full_width,page-template-full_width-php,page,page-id-19458,bridge-core-3.3.2,qi-blocks-1.3.3,qodef-gutenberg--no-touch,qodef-qi--no-touch,qi-addons-for-elementor-1.8.1,qode-page-transition-enabled,ajax_fade,page_not_loaded,,qode-title-hidden,qode-theme-ver-30.8.2,qode-theme-bridge,qode_header_in_grid,wpb-js-composer js-comp-ver-7.9,vc_responsive,elementor-default,elementor-kit-7

Tech Innovation    >    DC Infrastructure   >    Data Center Containment Rack

Tech Innovation

Data Center Containment Rack

Data Center Containment Rack is a system or technology designed to improve operational efficiency and environmental management in the Data Center. The main goal is to separate the flow of hot and cold air in the server space, so as to increase cooling, reduce energy consumption, and extend the life of IT equipment.

 

Basically, the Containment Rack functions to “confine” hot or cold air so as not to be mixed. There are two main types: Cold Aisle Containment and Hot Aisle Containment. In Cold Aisle Containment, server shelves are arranged in such a way that the cold air from the cooling system only flows into the front server area, while Hot Aisle Containment places the hot air produced by the server into a separate area, and then removed out of the room.

Without this solution, organizations face the following challenges:

Inefficient Data Center Operations

Without using the data center containment rack, inefficiencies will occur due to limited PAC/CRAC capacity, leading to increased cooling costs.
Cost-Saving Through Efficient Cooling

Implementing a data center containment rack helps save on cooling, leading to significant cost reduction and improved operational efficiency.
Enhanced Physical Security

Data center containment racks provide double protection by securing critical infrastructure and improving physical security.
Icon
Key Features & Capabilities
Data Center Containment Rack optimizes cooling efficiency, enhances security, and reduces operational costs.
Show Details
a. Hot Aisle/Cold Aisle Containment
  • Separates hot and cold air streams to prevent mixing with doors and panels.
  • Includes doors, panels, and barriers to isolate hot exhaust air from cold intake air.
b. Modular Design
  • Easily integrates with existing racks, scalable to accommodate growing data center needs.
c. Thermal Management
  • Improves airflow by directing cold air to equipment intakes and hot air to return vents.
  • Reduces hotspots and ensures consistent cooling.
d. Energy Efficiency
  • Reduces the workload on cooling systems by maintaining optimal temperatures.
  • Lowers power consumption and operational costs.
e. Durable Construction
  • Made from high-quality materials like steel or aluminum for long-lasting performance.
  • Designed to withstand high temperatures and heavy loads.
f. Flexible Configurations
  • Available in various sizes, customizable for specific rack types or cooling requirements.
g. Easy Installation
  • Designed for quick and straightforward setup with minimal downtime.
  • Often includes tool-less assembly for convenience.
h. Compatibility
  • Works with a wide range of server racks, cabinets, and cooling systems.
  • Supports both raised floor and non-raised floor environments.
i. Safety Features
  • Includes fire-resistant materials and secure locking mechanisms.
  • Ensures compliance with industry safety standards.
Icon
Business Benefits
Data Center Containment Rack improves cooling, boosts security, and optimizes data center efficiency.
Show Details
a. Improved Cooling Efficiency
  • Prevents hot and cold air mixing, ensuring servers receive cool air at the right temperature.
  • Enhances the effectiveness of CRAC (Computer Room Air Conditioning) units.
b. Reduced Energy Costs
  • Lowers the energy required for cooling by optimizing airflow.
  • Can significantly reduce PUE (Power Usage Effectiveness) metrics.
c. Increased Equipment Lifespan
  • Maintains stable temperatures, reducing thermal stress on servers and other hardware.
  • Minimizes the risk of overheating and hardware failure.
d. Enhanced Data Center Capacity
  • Allows for higher-density server deployments by improving cooling efficiency.
  • Maximizes the use of available space.
e. Environmental Sustainability
  • Reduces carbon footprint by lowering energy consumption.
  • Supports green data center initiatives.
f. Operational Reliability
  • Ensures consistent performance of IT equipment by maintaining optimal operating conditions.
  • Reduces downtime caused by thermal issues.
g. Cost-Effective Solution
  • Provides a high return on investment (ROI) through energy savings and improved efficiency.
  • Reduces the need for additional cooling infrastructure.
h. Scalability
  • Adapts to changing data center needs, supporting growth and expansion.
  • Can be easily reconfigured or expanded as requirements evolve.
i. Compliance with Standards
  • Helps data centers meet industry regulations and standards for energy efficiency and thermal management.
Icon
Use Cases
Data Center Containment Rack enhances cooling, security, and efficiency across data center industries.
Show Details
a. IT & Telecom
Largest segment, driven by cloud and 5G technology.
b. BFSI (Banking, Financial Services, Insurance)
High demand for low-latency trading and compliance features.
c. Healthcare
Growth due to Electronic Health Records (EHRs) and telemedicine.
d. Government & Defense
Focus on security and sovereign data storage for critical operations.
e. Retail/E-commerce
Supports omnichannel platforms and big data analytics for improved customer experience.
f. Manufacturing
IoT and Industry 4.0 adoption driving growth and innovation in production.
Icon
How We Can Help
As vendor agnostic system integrator, PT Trinet Prima Solusi helps organizations in:
Show Details
a. Assessment & Consultancy
    Provide the best solution with accurate and useful mitigation analysis for customers.
b. Seamless Integration
    Zero downtime, enhanced cooling efficiency, and future-proof scalability for data center operations.